# Andet

Diverse implantater der ikke falder ind under de andre implantatkategorier.

# Skabelon

[![MRI safe.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-safe.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-safe.png)[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)[![MRI Unsafe.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-unsafe.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-unsafe.png)

<table id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse:collapse;width:100%;height:357.563px;border-width:1px;background-color:rgb(236,240,241);"><colgroup><col style="width:29.4644%;"></col><col style="width:70.6548%;"></col></colgroup><tbody><tr style="height:29.7969px;"><td style="height:29.7969px;">**Fabrikat/model:**</td><td style="height:29.7969px;">  
</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Statisk feltstyrke:**</td><td style="height:29.7969px;">1,5 Tesla / 3 Tesla</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Scannerarkitektur:**</td><td style="height:29.7969px;">Ingen restrektioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Spatial gradient:**</td><td style="height:29.7969px;">X Gauss/cm (X T/m)</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Slew rate (Gr):**</td><td style="height:29.7969px;">Ingen restriktioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**SAR:**</td><td style="height:29.7969px;">Body: X W/kg

Head: X W/kg

</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**B1+rms:**</td><td style="height:29.7969px;">Ikke oplyst</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Coil type:**</td><td style="height:29.7969px;">Ingen restrektioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Artefakter:**</td><td style="height:29.7969px;">Ikke oplyst</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Temperaturstigning:**</td><td style="height:29.7969px;">Må kunne forventes</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Kilde (se evt. pdf):**</td><td style="height:29.7969px;">  
</td></tr></tbody></table>

<table id="bkmrk-kommentarer-til-impl" style="border-collapse:collapse;width:100%;height:59.5938px;border-width:1px;background-color:rgb(251,238,184);"><colgroup><col style="width:99.881%;"></col></colgroup><tbody><tr style="height:29.7969px;"><td style="height:29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">  
</td></tr></tbody></table>

# Craniefiksations systemer

Metal som benyttes efter operation i hjernen til at holde hjerneskallen på plads i kraniet.

# Craniofix 2

[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)

<table border="1" id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse: collapse; width: 100%; height: 357.563px; border-width: 1px; background-color: rgb(236, 240, 241);"><colgroup><col style="width: 29.4644%;"></col><col style="width: 70.6548%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Fabrikat/model:**</td><td style="height: 29.7969px;">CranioFix 2</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Statisk feltstyrke:**</td><td style="height: 29.7969px;">Maksimalt 3,0 Tesla</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Scannerarkitektur:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Spatial gradient:**</td><td style="height: 29.7969px;">Maksimalt 3.000 Gauss/cm (30 T/m)</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Slew rate (Gr):**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**SAR:**</td><td style="height: 29.7969px;">First Level Operating Mode

Maksimalt 4,0 W/kg (Body)

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**B1+rms:**</td><td style="height: 29.7969px;">Ikke oplyst</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Coil type:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Artefakter:**</td><td style="height: 29.7969px;">Ved SE: Maksimalt 503 mm2

Ved GE: Maksimalt 701 mm2

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Temperaturstigning:**</td><td style="height: 29.7969px;">Ved 1,5 Tesla: Maksimalt 2,6 grader (Ved scanning på First level O. M.)

Ved 3,0 Tesla: Maksimalt 2,8 grader (Ved scanning på First level O. M.)

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kilde (se evt. pdf):**</td><td style="height: 29.7969px;">Aesculapusa.com</td></tr></tbody></table>

<table border="1" id="bkmrk-kommentarer-til-impl" style="border-collapse: collapse; width: 100%; height: 59.5938px; border-width: 1px; background-color: rgb(251, 238, 184);"><colgroup><col style="width: 99.881%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">  
</td></tr></tbody></table>

# Hormonspiral

# Kyleena spiral

[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)

<table border="1" id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse: collapse; width: 100%; height: 357.563px; border-width: 1px; background-color: rgb(236, 240, 241);"><colgroup><col style="width: 29.4644%;"></col><col style="width: 70.6548%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Fabrikat/model:**</td><td style="height: 29.7969px;">Kyleena</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Statisk feltstyrke:**</td><td style="height: 29.7969px;">Maksimalt 3,0 Tesla</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Scannerarkitektur:**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Spatial gradient:**</td><td style="height: 29.7969px;">Maksimalt 36.000 Gauss/cm (360T/m)</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Slew rate (Gr):**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**SAR:**</td><td style="height: 29.7969px;">Maksimal WB SAR: 4,0 W/kg

First Level Operating Mode

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**B1+rms:**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Coil type:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Artefakter:**</td><td style="height: 29.7969px;">Maksimalt 5 mm fra implantatet</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Temperaturstigning:**</td><td style="height: 29.7969px;">Maksimalt 2,0 grader ved scanning i 15 min ved ovenstående WB-SAR-niveau</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kilde (se evt. pdf):**</td><td style="height: 29.7969px;">  
</td></tr></tbody></table>

<table border="1" id="bkmrk-kommentarer-til-impl" style="border-collapse: collapse; width: 100%; height: 59.5938px; border-width: 1px; background-color: rgb(251, 238, 184);"><colgroup><col style="width: 99.881%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">  
</td></tr></tbody></table>

# Sternale cerclage tråde (sternal wires)

[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)

<table id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse:collapse;width:100%;height:357.563px;border-width:1px;background-color:rgb(236,240,241);"><colgroup><col style="width:29.4644%;"></col><col style="width:70.6548%;"></col></colgroup><tbody><tr style="height:29.7969px;"><td style="height:29.7969px;">**Fabrikat/model:**</td><td style="height:29.7969px;">Sternale cerclage tråde (sternal wires) — generisk. Fremstillet af rustfrit stål, titanium eller nitinol. Anvendes til sternallukning efter sternotomi.</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Statisk feltstyrke:**</td><td style="height:29.7969px;">1,5 Tesla / 3 Tesla</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Scannerarkitektur:**</td><td style="height:29.7969px;">Ingen restrektioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Spatial gradient:**</td><td style="height:29.7969px;">Ingen restriktioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Slew rate (Gr):**</td><td style="height:29.7969px;">Ingen restriktioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**SAR:**</td><td style="height:29.7969px;">Body: 2,0 W/kg

</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**B1+rms:**</td><td style="height:29.7969px;">Ikke oplyst</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Coil type:**</td><td style="height:29.7969px;">Ingen restrektioner</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Artefakter:**</td><td style="height:29.7969px;">Må forventes i nærhed af sternum. Omfanget afhænger af materiale (stainless steel &gt; titanium/nitinol). Ingen sikkerhedsrisiko.</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Temperaturstigning:**</td><td style="height:29.7969px;">Må kunne forventes — særligt ved thoraxscanning og SAR-intensive sekvenser. Patient informeres om at melde varme eller ubehag.</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">**Kilde (se evt. pdf):**</td><td style="height:29.7969px;">- Baikoussis et al. (2011) — *Annals of Thoracic Surgery* — [https://www.annalsthoracicsurgery.org/article/S0003-4975(11)00495-4/fulltext](https://www.annalsthoracicsurgery.org/article/S0003-4975(11)00495-4/fulltext)
- Levine et al. (2007) — *Circulation / AHA* — [https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.107.187256](https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.107.187256)
- NHS GGC MRI Physics GISP + detaljeret litteraturgennemgang — [https://www.mriphysics.scot.nhs.uk/implant-safety-policies/sternal-wires-and-fixation-devices/](https://www.mriphysics.scot.nhs.uk/implant-safety-policies/sternal-wires-and-fixation-devices/)
- MRIquestions.com (Elster) — [https://mriquestions.com/sternal-wiresimplants.html](https://mriquestions.com/sternal-wiresimplants.html)

</td></tr></tbody></table>

<table id="bkmrk-kommentarer-til-impl" style="border-collapse:collapse;width:100%;height:59.5938px;border-width:1px;background-color:rgb(251,238,184);"><colgroup><col style="width:99.881%;"></col></colgroup><tbody><tr style="height:29.7969px;"><td style="height:29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height:29.7969px;"><td style="height:29.7969px;">Sternale cerclage tråde er fikseret til sternum og udgør ingen risiko for displacement eller migration i magnetfeltet. Et enkelt brud på en tråd er ikke en kontraindikation. Verificér at nålen er fjernet fra tråden inden scanning. Tjek operationsjournal for eventuelle øvrige implantater indsat under samme operation (fx epicardiale elektroder, vaskulære klips). Nitinol- og titaniumvarianter har generelt ingen yderligere restriktioner ud over standard SAR-hensyn.</td></tr></tbody></table>

# Brystimplantater

# Motiva (med RFID teknologi - Qid eller Zen)

[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)

<table border="1" id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse: collapse; width: 100%; height: 357.563px; border-width: 1px; background-color: rgb(236, 240, 241);"><colgroup><col style="width: 29.4644%;"></col><col style="width: 70.6548%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Fabrikat/model:**</td><td style="height: 29.7969px;">Motiva (med RFID teknologi - Qid eller Zen)</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Statisk feltstyrke:**</td><td style="height: 29.7969px;">1,5 Tesla / 3 Tesla</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Scannerarkitektur:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Spatial gradient:**</td><td style="height: 29.7969px;">4000 Gauss/cm</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Slew rate (Gr):**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**SAR:**</td><td style="height: 29.7969px;">Body: 2 W/kg

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**B1+rms:**</td><td style="height: 29.7969px;">Ikke oplyst</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Coil type:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Artefakter:**</td><td style="height: 29.7969px;">MR-scanning viser et **susceptibilitetsartefakt relateret til RFID-chippen**, som ses i den **posteriore del af implantatet**. <span class="inline-flex" data-state="closed">[<span class="relative transition-colors h-full max-w-[180px] overflow-hidden px-1.5 inline-flex items-center font-small rounded-full border-0.5 border-border-300 bg-bg-200 group-hover/tag:bg-accent-900 group-hover/tag:border-accent-100/60"><span class="text-nowrap text-text-300 break-all truncate font-normal group-hover/tag:text-text-200">Motivausa</span></span><span class="transition-all opacity-[0%] h-[17px] absolute right-[0.5px] inline rounded-r-full flex items-center px-1.5 bg-gradient-to-r from-accent-900/0 via-accent-900/100 via-30% to-accent-900/100 group-hover/tag:opacity-[100%]"><svg class="transition-all group-hover/tag:ease-out duration-[500ms] ease-in text-accent-100 group-hover/tag:scale-[100%] scale-[80%] group-hover/tag:opacity-[100%] opacity-[0%] -mr-[2px]" fill="currentColor" height="14" viewbox="0 0 256 256" width="14" xmlns="http://www.w3.org/2000/svg"><path d="M200,64V168a8,8,0,0,1-16,0V83.31L69.66,197.66a8,8,0,0,1-11.32-11.32L172.69,72H88a8,8,0,0,1,0-16H192A8,8,0,0,1,200,64Z"></path></svg></span>](https://motivausa.com/sites/default/files/2024-10/Motiva%20Implants%20DFU%20USA.pdf)</span>

Denne mikrotransponder kan skabe en **imaging void** (artefakt) under bryst-MR, som kan blokere visualisering af et **lille område af brudvæv nær Qid™**. I udvalgte tilfælde kan alternative billeddiagnostiske teknikker som ultralyd, tomosyntese eller digital kompression overvejes. <span class="inline-flex" data-state="closed">[<span class="relative transition-colors h-full max-w-[180px] overflow-hidden px-1.5 inline-flex items-center font-small rounded-full border-0.5 border-border-300 bg-bg-200 group-hover/tag:bg-accent-900 group-hover/tag:border-accent-100/60"><span class="text-nowrap text-text-300 break-all truncate font-normal group-hover/tag:text-text-200">Spiran</span></span><span class="transition-all opacity-[0%] h-[17px] absolute right-[0.5px] inline rounded-r-full flex items-center px-1.5 bg-gradient-to-r from-accent-900/0 via-accent-900/100 via-30% to-accent-900/100 group-hover/tag:opacity-[100%]"><svg class="transition-all group-hover/tag:ease-out duration-[500ms] ease-in text-accent-100 group-hover/tag:scale-[100%] scale-[80%] group-hover/tag:opacity-[100%] opacity-[0%] -mr-[2px]" fill="currentColor" height="14" viewbox="0 0 256 256" width="14" xmlns="http://www.w3.org/2000/svg"><path d="M200,64V168a8,8,0,0,1-16,0V83.31L69.66,197.66a8,8,0,0,1-11.32-11.32L172.69,72H88a8,8,0,0,1,0-16H192A8,8,0,0,1,200,64Z"></path></svg></span>](https://spiran.care/your-motiva-breast-implant-questions/)</span>

Motiva implantater vil ikke udgøre en yderligere risiko eller fare for patienten op til 3 Tesla MR-miljø hvad angår translationel attraktion eller migration, ifølge ASTM's acceptkriterier for deflektionsvinkel.

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Temperaturstigning:**</td><td style="height: 29.7969px;">Max 1,5°C</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kilde (se evt. pdf):**</td><td style="height: 29.7969px;">motivaimplantaty.cz</td></tr></tbody></table>

<table border="1" id="bkmrk-kommentarer-til-impl" style="border-collapse: collapse; width: 100%; height: 59.5938px; border-width: 1px; background-color: rgb(251, 238, 184);"><colgroup><col style="width: 99.881%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">Scantid: ≤ 15 min, eller ≤ 60 min kontinuerligt</td></tr></tbody></table>

# Implantater i galdegange

# Galdegangsclips af ukendt fabrikat

[![MRI safe.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-safe.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-safe.png)[![MRI Conditional.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-conditional.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-conditional.png)[![MRI Unsafe.png](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/scaled-1680-/mri-unsafe.png)](https://mrdb.friishns.eu/uploads/images/gallery/2026-04/mri-unsafe.png)

<table border="1" id="bkmrk-fabrikat%2Fmodel%3A-foru" style="border-collapse: collapse; width: 100%; height: 357.563px; border-width: 1px; background-color: rgb(236, 240, 241);"><colgroup><col style="width: 29.4644%;"></col><col style="width: 70.6548%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Fabrikat/model:**</td><td style="height: 29.7969px;">Galdegangsclips</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Statisk feltstyrke:**</td><td style="height: 29.7969px;">1,5 Tesla / 3 Tesla</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Scannerarkitektur:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Spatial gradient:**</td><td style="height: 29.7969px;">650 Gauss/cm</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Slew rate (Gr):**</td><td style="height: 29.7969px;">Ingen restriktioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**SAR:**</td><td style="height: 29.7969px;">Body: 1 W/kg pr. 20 min

Normal Operation Mode (Level 0) kan ikke anvendes ukritisk

</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**B1+rms:**</td><td style="height: 29.7969px;">Ikke oplyst</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Coil type:**</td><td style="height: 29.7969px;">Ingen restrektioner</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Artefakter:**</td><td style="height: 29.7969px;">Artefakter i området omkring implantatet må forventes</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Temperaturstigning:**</td><td style="height: 29.7969px;">Må kunne forventes</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kilde (se evt. pdf):**</td><td style="height: 29.7969px;">mrscanning.com</td></tr></tbody></table>

<table border="1" id="bkmrk-kommentarer-til-impl" style="border-collapse: collapse; width: 100%; height: 59.5938px; border-width: 1px; background-color: rgb(251, 238, 184);"><colgroup><col style="width: 99.881%;"></col></colgroup><tbody><tr style="height: 29.7969px;"><td style="height: 29.7969px;">**Kommentarer til implantat**</td></tr><tr style="height: 29.7969px;"><td style="height: 29.7969px;">  
</td></tr></tbody></table>